Anti-interference test: multiple remote controls operate simultaneously in the same field to verify no mutual interference. Test method: 5/10/20 sets of devices operate successively in the same field, checking for misoperation, crosstalk, and abnormal response. Lideral LD series supports dozens of sets in the same field (FHSS + independent pairing); multi-device stress testing is done before shipment. It is recommended to perform same-field testing during port procurement acceptance.
| Method | Multiple sets operating simultaneously |
| Standard | No crosstalk, no frame loss |
| Lideral | Dozens of sets |
Note:Acceptance testing should be executed according to the actual number of simultaneous devices.